> USING CONDITIONS
|
|
|

|
OPERATING PRESSURES
:
In the heat exchangers PICKER, the acceptable maximum
pressures
are, for the majority of the families of exchangers, of
:
Acceptable
maximum pressure (bar)
|
SHELL
side
|
TUBES
side
|
|
|
|
Families
E,F,H,K,M,R
|
Families
C,E
|
Families
F,H,K,M,R
|
Service
|
20
|
16
|
16
|
10
|
Test
|
30
|
24
|
24
|
15
|
The hydraulic tests are carried
out systematically and exclusively with
oil.
OPERATING TEMPERATURES :
In the heat exchangers PICKER equipped with nitrile O-rings,
the
maximum temperature of the heating fluid (shell side) can
reach
100°C. It is the basic standard.
In the heat exchangers PICKER equipped with fluorocarbon
O rings
("VITON"), the maximum temperature of the heating
fluid (shell side)
can reach 150°C.
If moreover they have a tube bundle with special tinning
Sn-Ag, this
limit is carried to 200°C.
|